Comeco logo

Advantages

  • Smallest in-head programmable transmitter
  • Pt100 and 8 T/C programmable ranges
  • 2- or 3-wire current and voltage output
  • Serial interface for configuration
  • In-head and DIN-rail versions
  • IP65 box and Ex housing available

Description

COMECO’s temperature transmitter TRC is part of a revolutionary new project for the smallest (in-head) and cheapest multi-input programmable transmitter. It has a universal input accepting Pt100 RTD and 8 thermocouples and a voltage or current 2- or 3-wire output linearly proportional to the measured temperature. This model allows
on-site selection of sensor type, input range and conversion direction as well as sensor failure reaction and no user calibration is necessary to be provided. TRC is available in a case for mounting inside sensor protection head, in a watertight box with high protection class, and in a case for mounting on DIN rail. The serial interface allows fast and easy configuration. Thanks to the combination of performance, reliability, simplicity, flexibility, and low price, the TRC transmitter is easy to use and very widely applicable.

Additional information

Монтаж

DIN rail, In box IP65, In head, In Ex housing

Корпус

18x90x58 mm, 80x80x60 mm, ø44×19 mm

Аналогов вход

RTD Pt100 – 1.385, Thermocouple (TC) B, Thermocouple (TC) E, Thermocouple (TC) J, Thermocouple (TC) K, Thermocouple (TC) N, Thermocouple (TC) R, Thermocouple (TC) S, Thermocouple (TC) T

Аналогов изход

0…10 V, 0…20 mA, 4…20 mA

Интерфейс

RS232

Захранване

8…36 VDC, 9…36 VDC

TRC transmitter

Temperature

Technical Specifications
Input (programmable)
Pt100 (w=1.385); 3-wire min. -200…max. 600 °C
Thermocouple “B”min. 200…max. 1800 °C
Thermocouple “E”min. -20…max. 600 °C
Thermocouple “J”min. -20…max. 900 °C
Thermocouple “K”min. -20…max. 1200 °C
Thermocouple “N”min. -20…max. 1200 °C
Термодвойка “R”min. 0…max. 1700 °C
Термодвойка “S”min. 0…max. 1700 °C
Термодвойка “T”min. -40…max. 400 °C
Input / output conversiondirect or reverse, programmable
Output
Option‘2’‘3’
Voltage0…10 V
– minimum load1 MΩ
Current 4…20 mA0(4)…20 mA
– maximum load800 Ω at 24V/20mA750 Ω at 24V/20mA
Sensor failure reaction 20,2 mA, programmabledownscale or upscale, programmable
Accuracy
Measurement error0.3% from span
Non-linearitywithin measurement error
Self-heating error0,005%/mA at 24 V
Temperature drift 0.01% from span for 1 °C
Cold junction compensationautomatic software, ± 0.5 °C
RTD 3-wire line compensation up to 25 Ω per wire
Interface
Interface typeRS232
Physical connectionrequiring special cable (2)
Configuration softwareTraCon”, free
Power supply
Supply voltage8…36 VDC9…36 VDC (1)
Admissible variations1 Vp-p at 50 Hz1 Vp-p at 50 Hz
Operating conditions
Ambient temperature-20…70 °C
Ambient humidity0…95 %RH, non-condensing

 

Design and materials
Case materialplastic
Wiringscrew terminals
Mountingin head (3,4,5)on rail in box (4)
Interface connector 4-pin 3-pin 4-pin
Interface cable type (2)K1, K11UK2, K12UK1, K11U
Dimensions [mm] ø44×1918x90x5880x80x60
Weight 30 g90 g170 g
Protection class IP20IP20IP65

(1) 13…36 VDC for output 0…10 V

(2) Ordered separately

(3) Head type “B” or any other with 33 mm distance between centers of the female threaded openings

(4) May be mounted on rail by a special snap-on accessory, which is ordered separately (see ‘Accessories’).

(5) May be mounted in different, separately ordered Ex housings for field applications (see ‘Accessor