Comeco logo

Advantages

  • 1500 VAC input / output isolation
  • Transmitter with universal programmable input
  • User-selectable 4 RTD types and 6 thermocouples
  • Accepts linear current, voltage, and resistive signals
  • Programmable input and output range
  • Built-in programmable digital filter
  • Manual output control
  • Serial interface for programming
  • IP65 box and Ex housing available

Description

The intelligent isolated transmitter TRBI, manufactured by COMECO, is available in case prepared for mounting in Ex housings, in casing for in-head mounting, and in another for DIN-rail mounting, as well as mounted into an IP65 protection box. This transmitter allows the user to:

  • select sensor and input signal type;
  • select and adjust input range;
  • perform offset correction and device calibration;
  • select sensor and input signal type (4…20 mA / 20..4 mA);
  • select decimal point position and measurement unit;
  • select output reaction at sensor failure;
  • adjust the digital filter.

TRBI is easy to program using the specialized “TraCon” software. Thanks to its large capabilities and low price, TRBI can be very useful in various industrial field applications requiring signal isolation. Technical specifications

Additional information

Монтаж

DIN rail, In box IP65, In head, In Ex housing

Корпус

18x90x58 mm, 80x80x60 mm, ø44×23 mm

Захранване

8…32 VDC

Аналогов вход

RTD Pt100 – 1.385, RTD Pt1000 – 1.385, RTD PTC 1k, RTD PTC 2k, Thermocouple (TC) B, Thermocouple (TC) J, Thermocouple (TC) K, Thermocouple (TC) R, Thermocouple (TC) S, Thermocouple (TC) T

Аналогов изход

20…4 mA, 4…20 mA

Интерфейс

RS232

TRBI transmitter

Temperature

Technical Specifications
Input
(programmable)
Pt100 (w=1.385); 3-wiremin. -100…max. 850 °C
Pt1000 (w=1.385); 3-wiremin. -100…max. 600 °C
PTC (1k at 25 °C); 3-wiremin. -50…max. 150 °C
PTC (2k at 25 °C); 3-wiremin. -50…max. 150 °C
RTD minimum range width50 °C
Thermocouple “T”min. -40…max. 400 °C
Thermocouple “J”min. -20…max. 1000 °C
Thermocouple “K” min. -20…max. 1300 °C
Thermocouple “S”min. 0…max. 1700 °C
Thermocouple “R”min. 0…max. 1700 °C
Thermocouple “B” min. 200…max. 1800 °C
T/C minimum range width100 °C
Linear current0(4)…20 mA
Linear voltage0…100 mV or 0…10 V (1)
Linear resistive0…1 kΩ
Custom linear (option)on request (2)
Offset adjustmentwithin range limits
Digital low-pass filterprogrammable
Digital peak filterprogrammable
Input / output isolation1500 VAC for 1 min
Input monitoring
(programmable)
Sensor failure reaction 20,2 mA,
programmable
Output(probrammable)
Signal type4…20 mA or20…4 mA
Linearly proportional tomeasured value
Resolution 4 µA
Output calibrationthrough interface
Manual output control0…100%, programmable
Accuracy
Measurement error 0.3% from span
Non-linearitywithin measurement error
Temperature drift0.01% from span for 1 °C
Cold junction compensationautomatic software, ± 0.5 °C
Power supply
Supply voltage8…32 VDC ± 10%
Maximum line load750 Ω at 24V/20mA
Interface
Interface type RS232 based
Physical connectionrequiring special cable (3)
Configuration softwareTraCon”, free
Operating conditions
Ambient temperature-20…70 °C
Ambient humidity0…95 %RH, non-condensing
[table “” not found /]



(1) Ask for availability!

(2) Instead of linear current

(3) Ordered separately

(4) Head type “B” or any other with 33 mm distance between centers of the female threaded openings

(5) May be mounted on rail by a special snap-on accessory, which is ordered separately (see ‘Accessories’).

(6) May be mounted in different, separately ordered Ex housings for field applications (