Comeco logo

Advantages

  • 100% 2-wire AC/DC transmission
  • Case for mounting inside current transformers available
  • Reliable and accurate conversion
  • High EMS suppression
  • Input isolation option
  • ZERO and SPAN adjustment
  • In-head and DIN-rail versions
  • IP65 box and Ex housing available

Description

The current-to-current transmitter TRT is designed to convert alternative current signal coming from current transformers into a standard 2-wire current signal, which is more suitable for transmitting. Together with a current transformer, the TRT unit forms an AC/DC current converter suitable to measure big AC currents up to more than 1000 A. The 4…20 mA output can be used for measuring, regulation, and registration in special control systems. The TRT transmitter is based on modern integrated circuits and is a fixed-range transmitter. Its input ranges cover most popular current transformer output signals (0…1 A, 0…5 A) and customer specified inputs as well. TRT is available in a casing for mounting inside a current transformer, in 2 casings for DIN-rail mounting as well as mounted into an IP65 protection box, as the latter 3 versions can be equipped with an optional input isolation. TRT is an easy-to-use, low-cost, and EMS- protected device. Its application area includes power stations, electrical equipment, and electricity production and distribution. This transmitter can also be used as sensor transducer in various industrial control systems and everywhere, where AC to DC current conversion is desirable.

Additional information

Монтаж

DIN rail, In box IP65, Free, In socket

Корпус

35x110x58 mm, 35x78x91 mm, 43x33x16 mm, 80x80x60 mm

Захранване

115 VAC, 230 VAC, 8…32 VDC

Аналогов вход

0…1 A AC linear current, 0…5 A AC linear current, Other

Аналогов изход

4…20 mA

TRT transmitter

Current / Voltage / ResistanceTemperature

Technical Specifications
Input
Input signalalternative current
Frequency50/60 Hz
Input range0…1 A or 0…5 A
Other input ranges0…max. 10 A
Input isolation (option) (1)internal current transformer
Output
Output signal 4…20 mA, 2-wire
Current limits Low = 3 mA, High = 28 mA
ZERO and SPAN adjustment ± 10%, via trimpots
Maximum line load800 Ω at 24V/20mA
Accuracy
Measurement error at 25 °C0.5% from span
Non-linearity0.5% from span
(up to 1.0% w/ input isolation)
Temperature drift0.1% from span for 1 °C
Supply voltage variation influence0.02% from span for 1 V
Power supply
Mains supply voltage230 VAC or 115 VAC(2)
Isolated low voltage (2)12…24 V
Non-isolated low voltage8…32 VDC
Admissible variations10% p-p at 50 Hz
Operating conditions
Ambient temperature-20…70 °C
Ambient humidity
– mounted in a transformer0…80 %RH, non-condensing
– mounted on a rail 0…95 %RH, non-condensing
– mounted in a box0…95 %RH
Design and materials
Mountingfreein box (3)on railin socket (4)
Dimensions [mm]43x33x1680x80x6035x110x5835x78x91
Weight20 g110 g90 g180 g
Protection, case/terminalsIP40/20IP65IP20IP20
Case materialplasticplasticplasticplastic
Wiringscrew terminalsscrew terminalsplug-in terminalssocket UNDECAL (5)

(1) Not available for the version for free mounting (G12 = “B”)!

(2) Only for the version for mounting in socket

(3) May be mounted on rail by a special snap-on accessory, which is ordered separately (see ‘Accessories’).

(4) May be also mounted on a DIN rail

(5) Ordered separately (see ‘Accessories’)